Input: 0 to 1mV ; impedance: 10 kΩ
Output: 0 to 10V, on load ≥ 2 kΩ
Accuracy: better than 0.3%
Regulation: < 5.10-4, with load varying from 2kΩ up to 100kΩ
Ripple: < 100 mV
Response time: ≈ 200 µs (can be increased upon request)
Isolation: triple, with input/output, input/supply and output/supply: 3kV
Power supply voltage: standard, 24V DC ± 10% /  < 40 mA / load 2 kΩ
Possible load: ≥ 2kΩ
Protections:
- against inverted connections on input and power supply
- against accidental overvoltage on input: 1V
- against overloads and short-circuits
- isolations 3000V
- against vibrations, and tropicalisation: with moulding
- sealing iP67, except connections
- elimination of the faulty-contact risk (no DIL switch)
- negligible temperature rise (high performance conversion)
Standards: CE ; RoHS ; EN 60905-1
Temperatures:
- coefficient: < 2.10-4 / °C
- operation: -20°C to +60°C
- storage: – 40°C to + 90°C
Three modules:
- DIN rail mounting (RD)
- wall mounting with external connector and 2 M3 screws (P)
- mounting on printed circuit, connecting pins Ø 1mm (CI)
Optional: all-aluminum case
For more information about this isolated signal converter 0 to 1mV into 0 to 10V: PDF